Asplit VEL防腐施工方案
来源:卡德环氧地坪网   http://www.kade.cn     字体:      
一. 防腐施工前的准备工作和基面处理
Pre-clean the surface, degrease agent will be used to remove the oil on the floor if necessary.
预清洁表面,必要时使用清洗剂除去表面油污
 
surface preparation:
基面处理
 
Carry out surface preparation by Grinder and dust free self-enclosed portable grinder until to
remove surface laitance and provide sound and textured surface.
使用地坪打磨机和无尘封闭手提磨机去除表面粗糙物,并提供涂装对表面所要求
的粗糙度。
 
Cleaning floor by using high pressure washing machine with potable water
高压洁净水冲洗表面
 
Remove all remaining dust and debris by dry sweeping and then vacuum cleaning after concrete
surface drying.
混凝土表面干燥后,先用扫帚扫去地表残留灰尘和杂物,然后用真空吸尘器进一步
清洁表面。
 
Before beginning of the coating works, the water content of the floor surface should not be higher
than 4%.
实施涂装前,表面含水量不得高于4%
 
二. Asplit VEL laminates: Asplit VEL防腐层压系统施工方案
 
Mix Asplit VE primer:
搅拌Asplit VE防腐涂料
 
Mix solution and hardener of Asplit VE(100:1.5) with a low speed mixer for about 3 minutes. Then
 add VE powder (the ratio of solution and powder is 100:80) into mixture, mix for 3 minutes again.
Pour the mixture into a big and clean drum and mix again.
将Asplit VE树脂和固化剂(比例:100:1.5)二种组份混合后,低速搅拌约三分钟。然后再加
入VE粉料(VE 树脂:粉料=100:80),搅拌三分钟。将搅拌后的混合物倒进一干净大
桶中,再行搅拌。
 
Scratch one coat of sealer (solution:hardener:VE powder=100:1.5:80)
刮涂底漆,涂布率为
- Asplit VE @ 0.50 kg/m2.
 
Allow the sealer coat to cure for at least 20 hours.
底漆固化容许时间至少20小时
 
Roller one coat of Asplit VE(solution:hardener=100:1.5)
辊涂中间层Asplit VE防腐涂料
- Asplit VE @0.2 kg/m2
 
Immediately install one layer of glass mat (300 g/m2). Overlap should have a width of about 4cm.
马上敷设一层短切毡(300克/平方米).每块短切毡必须重叠4cm。
Asplit VE @ 0.85 kg/m2
 
Pressed in with the roller and simultaneously satulated with Asplit VEL binding material. Remove the
air bubbles inside the glass mat by steel disk roller.
用钢片滚筒压实,Asplit VE 防腐涂料 必须完全浸润短切毡,并除去残留在玻璃纤维布
内的气泡。
 
Apply one coat of Asplit VE again , then immediately Lay one layer of glass mat (300 g/m2) . Overlap
should have a width of about 4cm. Pressed in with the roller and simultaneously satulated with Asplit VEL
binding material. Remove the air bubbles inside the glass mat by steel disk roller.
再次辊涂中间层Asplit VE防腐涂料一层, 马上敷设一层300g/m2的短切毡, 每块短切毡必须
重叠4cm。同时用钢片滚筒压实,Asplit VE 必须完全浸润短切毡,并除去残留在玻璃纤维布
内的气泡。
- Asplit VE @ 0.85 kg/m2
 
Roller apply one coat of Asplit VE again, then install Surface fleece (30 g/m2), all application are same as
5,6 and 7 section.
辊涂中间层Asplit VE防腐涂料一层, 马上敷设一层薄型织物(30克/平方米)。所有操作同5,
6,7。
- Asplit VE @ 0.85 kg/m2
 
Roller one coat of Asplit VE (RAL 7032, solution : hardener=100:1) after Asplit VE laminating layer
curing 3-5 hours.
在中间层Asplit VE防腐涂料固化后3-5 小时,再敷设,辊涂一道颜色为RAL 7032的Asplit VE
- Asplit VE @ 0.30kg/m2
 
Note 注意事项:
1.     由于底涂和中涂均为Asplit VE防腐涂料,且短切毡必须在Asplit未固化前敷设,
所以从第4-8步骤为连续作业。每块短切毡以及薄型织物 必须重叠4cm。
2.     Asplit VE防腐涂料的固化时间很短,可以通过调节A、B组份的配比来调节固化时
间。A、B组份的通常配比为100:1.5。可根据现场温度进行调节的区间为100:(0.7-1.5),
温度越高,B组份比例越少。
3.     由于Asplit VE防腐涂料的固化时间很短,所以应根据施工条件确定搅拌量,不应
整套搅拌。施工过程中若发现搅拌后的Asplit防腐涂料已开始固化,应立即丢弃,不
得再次用。
4.     面涂用的Asplit VE防腐涂料配比为100:1.
Note 注意事项:
Check the environmental data. No application can be carried out when one of the followings
happens
检测环境参数,下列任一情况如有发生,即应停止施工
·       Relative humidity (RH) is more than 80 %.
相对湿度(RH)大于80%
·       Temperature is lower than 10℃.
气温低于10℃.
·       Surface temperature is 3℃ less than Dew-point.
表面温度低于露点温度3℃.
Method Statement
Coating Works with Glass-mat with Asplit ET Materials
Asplit ET防腐施工方案
 
一. 防腐施工前的准备工作和基面处理
  • Pre-clean the surface, degrease agent will be used to remove the oil on the floor if necessary.
预清洁表面,必要时使用清洗剂除去表面油污
  • surface preparation:
基面处理
Carry out surface preparation by Grinder and dust free self-enclosed portable grinder until to remove
surface laitance and provide sound and textured surface.
使用地坪打磨机和无尘封闭手提磨机去除表面粗糙物,并提供涂装对表面所要求的粗糙度。
  • Cleaning floor by using high pressure washing machine with potable water
高压洁净水冲洗表面
  • Remove all remaining dust and debris by dry sweeping and then vacuum cleaning after concrete s
  • urface drying.
混凝土表面干燥后,先用扫帚扫去地表残留灰尘和杂物,然后用真空吸尘器进一步清洁。
  • Before beginning of the coating works, the water content of the floor surface should not be higher
  • than 4%.
实施涂装前,施工表面含水量不得高于4%
二. Asplit ET laminate: Asplit ET层压防腐施工方案
  • Mix Asplit ET primer
搅拌Asplit ET防酸涂料
Mix solution and hardener of Asplit VE(100:20) with a low speed mixer for about 3 minutes. Pour the
mixture into a big and clean drum and mix again.
将Asplit ET树脂和固化剂(100:20)二种组份混合后,低速搅拌约三分钟。将搅拌后混合物倒
进一干净大桶中,再行搅拌。
  • Roller one coat of Asplit ET(solution:hardener=100:20)
辊涂底层Asplit ET防腐涂料
- Asplit ET @0.2 kg/m2
  • Immediately install one layer of glass mat (300 g/m2). Overlap should have a width of about 4cm.
马上敷设一层短切毡(300克/平方米).每块短切毡必须重叠4cm。
Asplit ET @ 0.85 kg/m2
  • Pressed in with the roller and simultaneously satulated with Asplit ET binding material. Remove the
  • air bubbles inside the glass mat by steel disk roller.
用钢片滚筒压实,Asplit ET 防腐涂料必须完全浸润短切毡,并除去残留在玻璃纤维布内的气泡。
  • Apply one coat of Asplit ET again , then immediately Lay one layer of glass mat (300 g/m2) . Overlap s
  • hould have a width of about 4cm. Pressed in with the roller and simultaneously satulated with Asplit ET binding material. Remove the air bubbles inside the glass mat by steel disk roller.
再次辊涂中间层Asplit ET防腐涂料一层, 马上敷设一层300g/m2的短切毡,每块短切毡必须重叠4cm。
同时用钢片滚筒压实,Asplit ET必须完全浸润短切毡,并除去残留在玻璃纤维布内的气泡。
- Asplit ET @ 0.85 kg/m2
  • Roller apply one coat of Asplit ET, then install Surface fleece (30 g/m2), all application are same as 2,3
  • and 4 section.
辊涂中间层Asplit ET防腐涂料一层, 马上敷设一层薄型织物(30克/平方米)。所有操作同上。
- Asplit ET @ 0.85 kg/m2
  • Roller apply top coat of Asplit ET topcoat
(solution :hardener:fine grey powder=100:20:50)
辊涂加有填料的Asplit ET面漆
- Asplit ET(with fine grey powder) @ 0.30kg/m2
 
Note 注意事项:
Check the environmental data. No application can be carried out when one of the followings happens
检测环境参数,下列任一情况如有发生,即应停止施工
·       Relative humidity (RH) is more than 80 %.
相对湿度(RH)大于80%
·       Temperature is lower than 10℃.
气温低于10℃.
·       Surface temperature is 3℃ less than Dew-point.
表面温度低于露点温度3℃.
  • 机械强度高,抗磨损和抗冲击性能优异
  • 经长期使用,漆膜性能依然良好
  • 在钢和水泥底材上附着力良好
  • 是含焦油类涂料的理想替代品
  • 使用寿命长,维护简便,性能价格比高
  • 可刷涂或滚涂在金属或其它封闭过的底材表面,施工简便
  • 可直接空气或无气喷涂在金属或封闭过的底材表面
  • 溶剂含量低,符合腐蚀防护协会的有关规定(VdL)
2. 使用范围
Permacor 3326/EG防腐涂料非常适用于直接和水以及其它化学品接触的钢材和水泥底材的防护。
Permacor 3326/EG防腐涂料同样也适和在工业环境下提供坚固耐用的防腐保护涂层,如用于保护
管道桥梁、储罐、管线、工厂以及机械设备等。
Permacor 3326/EG防腐涂料也可耐废水和许多化学品,详情请参阅Permacor耐化学品性能表。
特殊配方,专用于刷涂和滚涂
3. 包装和颜色
包装:
基料:10 kg;固化剂: 2.3 kg
颜色:
浅灰Grey c. RAL7024;绿色Green DB 601
 
其它颜色可按客户要求提供
漆膜外观:
无光
4. 技术数据
主要组分:
Permacor 3326/EG-H:环氧树脂,含少量溶剂
Permacor固化剂
3326/H-00:胺类化合物
密度(混合后):
1.9 g/cm3
固体含量(混合后):
体积比: 75 %(395 ml/kg)
重量比: 88 %
理论涂布率:
干膜厚度150微米: 5.0m2/l(2.6 m2/kg)
干膜厚度150微米: 0.38 kg/m2
理论用量:
实际用量取决于底材表面结构和施工方法
耐热性能:
干燥条件下: 连续耐热温度120℃
短期使用温度150℃
潮湿/液体环境下: 详情请向本公司查询
储存寿命:
凉爽干燥条件下,原包装可保存12个月
5. 使用指南
施工应由合格承包商及经专业培训的施工人员进行
表面处理:
 
钢材
喷砂清理至少达 Sa 2.5级(ISO 12944-4),中等粗糙度(G),平均表面粗糙度RY5 ≥ 50微米。 喷砂处理应使用经过测试并认可的磨料
混凝土
需涂装的混凝土底材表面应符合一般建筑标准,坚固、清洁、干燥,无可能影响附着力的杂质。水泥的含水率应小于4%(重量比),所有表面附着强度都应大于1.0N/mm2,且平均表面附着强度大于1.5N/mm2;当承受较高的机械荷载时,平均表面附着强度值应大于2.0N/mm2,最低不得小于1.5N/mm2。可配合适当的底漆使用,但应遵循正确的重涂间隔
施工和干燥温度:
最低10℃(底材表面和环境温度)
相对湿度:
最大80 %(施工温度应至少高于露点3℃)
当温度接近此界限时,建议使用加热器或干燥设备
产品混合:
彻底搅拌基料和固化剂。按给定的比例添加固化剂。
使用电动搅拌器充分混合均匀
混合比例:
重量比:   基料:固化剂=100:23
涂料准备:
根据具体要求,按照如下方法加入稀释剂:
刷涂/滚涂: 0 - 5% 稀释剂 E+B
清洗剂:
稀释剂E+B
混合后使用期:
20℃ 时:约1.5小时
干燥/固化(20℃):
表干 4小时
 
最小重涂间隔 12小时
用于储罐内衬时,建议至少48小时后重涂
 
完全固化:12小时
7天后,漆膜具有充分的机械和耐化学品性能
针孔/漏涂检测:
用适当的高压测试器对涂层进行火花试验 (例如 带有橡胶叶片的
Fischer Poroscope H2D/H8D)。测试电压为5伏每微米。
*注意:经多次测试后,漆膜的完整性可能会受影响
重涂性能:
自身,暴露在户外时与Permacor环氧或丙烯酸聚氨酯面漆配套使用(如2300
系列)。
有关Permacor涂料相容性的详情,请向本公司查询
6. 推荐油漆配套
配套 A: 与废水、盐水以及化学品接触的钢结构的防护
施工方法:刷涂/喷涂
涂层
3道Permacor 3326/EG-H
建议每道干膜厚度150微米
底材
参照“表面处理:钢材”部分


配套B: 污水池的防护
涂层
3道Permacor 3326/EG-H
建议每道干膜厚度150微米
底漆
一道Betonol G 177
填平砂浆
一道Betonol S 165
划痕涂层
一道Betonol S 165
底材
参照“表面处理:混凝土”部分
配套 C: 污水池裂缝修补的涂装
涂层
3道Permacor 3326/EG-H
建议每道干膜厚度150微米
层压层2
(如需要)
一道Betonol G 177
用于埋入Betonol专用玻璃毡
层压层1
一道Betonol G 177
用于埋入Betonol专用玻璃毡
填平砂浆
一道Betonol S 165
划痕涂层
一道Betonol S 165
底材
参照“表面处理:混凝土”部分
 
上一条 上一条:清水混凝土涂料的研制和应用
下一条 下一条:PCCP混凝土管及钢管内防腐方案
返回】【关闭】【打印】【收藏本页  
 